ECCO2 is designed to work with the EAGLE
(compatible with EAGLE4, EAGLE LE, EAGLE3 and EAGLE2 – in order to work
with EAGLE2 it requires update of OS and EAGLE Manager to v3) and, in
order to automatically control dew heater power it doesn’t need any
external software. In order to use the ECCO2 with EAGLE, please follow
these steps:
1) Connect temperature sensors to the ECCO2:
temperature sensor ports in the ECCO2 are numbered in the same order as
the dew heater ports on the EAGLE. Connect temperature sensor to the
ECCO2 port number corresponding to the port number on the EAGLE where
you connected the dew heater. For example, if your telescope dew heater
is connected to port 5 of your EAGLE, connect the temperature sensor to
the port 5 of the ECCO2. Please do not connect the other side (the
probe) to your telescope since, before start using the ECCO2,
temperature probes will have to be calibrated. Please have the
temperature probes free and not connected to different objects: for
example you can leave them on the table or hanging freely.

2) Click on the ECCO button in the EAGLE Manager interface and, after a few seconds, ECCO2 will activate.

3) The ports of the ECCO2 where you connected the temperature sensors, will become red.
This means that the temperature sensors have to be calibrated. When the
temperature sensors are not calibrated, ECCO2 LED light is flashing.
4) In the EAGLE Manager, please click the ADVANCED SETTINGS button, this will open a new window. In the top right part of the new window, you will see the CALIBRATE button.

5) Click on the CALIBRATE button
and you will see a red icon that will appear during calibration. When
the calibration is complete you will see a “Calibration OK”
notification, click OK to confirm and then click OK in the ADVANCED
SETTINGS window to close.
6) The port (you connected both the dew heater and the temperature sensor) will become orange
and this means ECCO2 is automatically controlling the dew power based
on the dew point that will be displayed on the EAGLE Manager interface.
From this moment ECCO2 takes control of the dew heater power based on
the dew point and you can’t manually control power of the dew heater
port in the EAGLE until you disconnect the temperature probe from the
ECCO2.

7) Insert the temperature probe head between the dew heater you want to automatically control with the ECCO2 and the telescope optical tube.

8) Temperature readings in the ECCO2 are displayed in Celsius (°C). If you want to see temperatures in Fahrenheit (°F), please go to ADVANCED SETTINGS and select “°F” in Temperature option.